HO5V-U HO7V-U
APPLICATION
IN DRY ROOMS, SWITCH AND DISTRUBITION BOARDS, FOR LAYING IN CONDUIT ON AND UNDER PLASTER AND ON INSULATING SUPPORTS ABOVE PLASTER.
HO7V-R
APPLICATION
IN DRY ROOMS, SWITCH AND DISTRUBUTION BOARDS, FOR LAYING IN CONDUIT ON AND UNDER PLASTER AND ON INSULATING SUPPORTS ABOVE PLASTER.
H05V-K H07V-K
APPLICATION
FOR PROTECTED INSTALLATION IN EQUIPMENT AND LIGHTING FITTING. ALSO FOR CONDUIT, ON AND UNDER PLASTER.
HO5VV-F
APPLICATION
USED AS CONNECTION CABLES, IN DRY AND HUMID PLACES THAT THERE ARE NOT MUCH MECHANICAL STRESS, GENERALLY USED IN HOUSEHOLD EQUIPMENTS.
HO5VV-U (NVV) HO5VV-R (NVV)
APPLICATION
USED IN DRY AND HUMID AREAS THAT THERE ARE NOT ANY MECHINAL STRESS, UNDER AND ON THE PLASTER.
YVV-U, NYY YVV-R, NYY
APPLICATION
WHERE MECHANICAL DAMAGE IS UNEXPECTED IN DOORS, UNDERGROUND, IN CABLE DUCTS AND INDUSTRIAL PLANTS TO BE POWER CABLES.
YVV-U, NYY YVV-R, NYY
APPLICATION
USED CABLE DUCTS AND UNDERGROUND, INTERIOR AND EXTERIOR THAT THERE ARE NOT ANY MECHANICAL STRESS.
YVV-U, NYY YVV-R, NYY
APPLICATION
USED CABLE DUCTS AND UNDERGROUND, INTERIOR AND EXTERIOR THAT THERE ARE NOT ANY MECHANICAL STRESS.
H05VV5-F (NYSLYÖ-JZ)
APPLICATION
THIS TYPE OF CABLES ARE SUITABLE AS MEASURING, MONITORING AND CONTROL CABLE FOR MANUFACTURING OF MACHINERY, IN ENGINEERING AND POWER STATIONS, IN HEATING OR AIR CONDITIONING AND OTHER ELECTRICAL SYSTEMS IN DRY AND DAMP OIL, INTERIORS, ESPECIALLY UNDER INDUSTRIAL ENVIRONMENTAL CONDITIONS.THESE CABLES ARE NOT USED IN THE OPEN AIR.
H03VH-h
APPLICATION
ON THE APPLICATIONS OF EQUIPMENT WITH LOW CURRENT.
YVV, NYY FLEX
APPLICATION
WHERE MECHANICAL DAMAGE IS UNEXPECTED IN DOORS, UNDERGROUND, IN CABLE DUCTS AND INDUSTRIAL PLANTS TO BE POWER CABLES.
TTR FLEX
APPLICATION
USED CABLE DUCTS AND UNDERGROUND, INTERIOR AND EXTERIOR THAT THERE ARE NOT ANY MECHANICAL STRESS.
H07VV-H06-F
APPLICATION
THIS CABLE USEFUL FOR LIFT AND SUBMERSIBLE PUMPS.
H05Z1-K H07Z1-K
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSIN CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
H05Z1-U H07Z1-U H07Z1-R
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
NHXMH-O NHXMH-J
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
H03Z1Z1-F H05Z1Z1-F
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
N2XH
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
N2XH
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
N2XH
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
N2XH
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
N2XH
APPLICATION
USED IN ENERGY NETWORKS IN REFINERIES, MINES, HOTELS, SCHOOLS, TUNNELS, HIGH CONSTRUCTIONS, HOSPITALS, POWER PLANT, DATA PROCESSING CENTERS, BUSINESS CENTERS WHERE THERE IS A RISK OF FIRE.
YXV N2XY
APPLICATION
THIS CABLE HAVE A LOW DIEELECTRIC LOSS AND USED INDOOR, IN CABLE DUCTS AND IN INDUSTRIAL PLANTS OR SWITCHING STATIONS WHERE MECHANICAL DAMAGE IS NOT ANTICIPATED. SUITABLE FOR COMPARATIVELY HIGH AMBIENT TEMPERATURE DUE TO HIGH MAXIMUM PERMISSIBLE CONDUCTOR TEMPERATURE.
YXV N2XY
APPLICATION
THIS CABLE HAVE A LOW DIEELECTRIC LOSS AND USED INDOOR , IN CABLE DUCTS AND IN INDUSTRIAL PLANTS OR SWITCHING STATIONS WHERE MECHANICAL DAMAGE IS NOT ANTICIPATED. SUITABLE FOR COMPARATIVELY HIGH AMBIENT TEMPERATURE DUE TO HIGH MAXIMUM PERMISSIBLE CONDUCTOR TEMPERATURE.
YXZ2V 2XRY
APPLICATION
INSTALLATION UNDERGROUND, INDOOR, IN DUCTS AND IN THE OPEN AIR WHERE MECHANICAL PROTECTION IS REQUIRED AGAINST HIGHER TENSILE STRESS DURING INSTALLATION AND OPERATION. SUITABLE FOR COMPARATIVELY HIGH AMBIENT TEMPERATURE DUE TO HIGH MAXIMUM PERMISSIBLE CONDUCTOR TEMPERATURE.
YVŞV NYFGBY
APPLICATION
INSTALLATION UNDERGROUND, INDOOR, IN DUCTS AND IN THE OPEN AIR WHERE MECHANICAL PROTECTION IS REQUIRED AGAINST HIGHER TENSILE STRESS DURING INSTALLATION AND OPERATION.
YVŞV NYFGBY
APPLICATION
INSTALLATION UNDERGROUND, INDOOR, IN DUCTS AND IN THE OPEN AIR WHERE MECHANICAL PROTECTION IS REQUIRED AGAINST HIGHER TENSILE STRESS DURING INSTALLATION AND OPERATION.
YVŞV NYFGBY
APPLICATION
INSTALLATION UNDERGROUND, INDOOR, IN DUCTS AND IN THE OPEN AIR WHERE MECHANICAL PROTECTION IS REQUIRED AGAINST HIGHER TENSILE STRESS DURING INSTALLATION AND OPERATION.
YVOV NYRY
APPLICATION
INSTALLATION UNDERGROUND, INDOOR, IN DUCTS AND IN THE OPEN AIR WHERE MECHANICAL PROTECTION IS REQUIRED AGAINST HIGHER TENSILE STRESS DURING INSTALLATION AND OPERATION.
YAVV
APPLICATION
USED AS ILLUMINATION CABLE IN ENERGY NETWORKS THAT THERE ARE NOT ANY MECHANICAL STRESS IN THE EXTERIOR, UNDER GROUND, IN CABLE CANALS AND IN WATERING FOUNDATIONS.